Optical transmission hardware integration one-stop service provider
You are here: Home / News

construction

The articles shown below are all about the construction, through these related articles, you can get relevant information, notes in use, or latest trends about the construction. We hope these news will give you the help you need. And if these construction articles can't solve your needs, you can contact us for relevant information.
[Knowledge] Application Scenarios for Oversized Fiber Optic Cables
Increasing the number of optical fiber cores is the most efficient way to increase the transmission capacity of fiber optic cable lines. However, it will also bring a series of problems such as fiber diameter is too thick, fiber can not be identified, repair difficulties and so on. This article will
Read More
[Knowledge] What Is The Difference between Communication Cement Pole And Anticorrosive Wood Pole in Use?
1 IntroductionBefore 1980s, preserved wood poles (hereinafter referred to as "wood poles") were mostly used in communication lines. At that time, wooden poles were often called tarred poles because the preservation of wooden poles was treated with tar at post offices or long-distance service station
Read More
[Knowledge] What Scenarios are ODN Unequal Scores Applicable to?
1 unequal score optical adaptation scenario analysisTraditional unequal score optical ODN introduction of fiber optic lines usually use a tree network structure, each splitter box is equivalent to the "leaves", generally assigned 2 cores (a master and a standby), the structure can be adapted to a va
Read More
[Knowledge] What is Pre-connected ODN?
1 IntroductionIn ODN, from the service aggregation point to the user is generally divided into backbone, distribution, introduction, home multiple segments. The construction of the introduction section of the traditional ODN cable involves a large number of fiber core splices. In the user installati
Read More
[Knowledge] What Are The Main Laying Methods of Fiber Optic Cable?
Due to different construction conditions and construction requirements, communication cables in different scenarios will take different laying methods, common laying methods include: direct burial, aerial, pipeline, underwater and bureau and so on.1 direct burial layingDirect burial,
Read More
[Knowledge] How Do We Choose A Server Room Cabinet?
With the development of data center construction towards overall availability, there is a growing demand for cabinet management in server rooms. Users should consider the following factors when purchasing cabinets:1, load-bearing guarantee: with the increased density of products placed in the cabine
Read More
[Knowledge] 1U, 2U, 3U, How Much Do You Know about the Size of the Cabinet?
Among the rackmount server sizes, the common ones are 1U server, 2U server, 4U server, the size of these servers are: 1U=4.445cm, 2U=4.445*2=8.89cm, 4U=4.445*4=17.78cm. In practice, 1U or 2U servers are most often used. Because the service provider is based on the space occupied by the server to cal
Read More
[Industry News] Insight into the second half of the fiber optic cable market
Since the fourth quarter of 2022, the fiber optic cable industry is facing a lack of orders, low start rate situation, mainly due to China Mobile, China Telecom did not start the ordinary fiber optic cable, outdoor fiber optic cable collection bidding project, to the fiber optic cable manufacturers
Read More
[Knowledge] Research on the faults and response methods of ordinary fiber optic cable for electric power communication
Power communication fiber optic cables are very prone to failures in data transmission, which are generally manifested as reduced transmission rate, poor transmission quality, transmission interruption and so on. In the face of such a situation, reasonable means should be taken to deal with the fail
Read More
[Knowledge] Advantages of Using Patch Panel
1、From the design point of view Comprehensive wiring has a point requirement if you have noticed, that is, the information point requires data, voice points can be interchanged when necessary
Read More